user_mobilelogo

Unter VMS 6.2 Verwendeten wir die Alpha Workstation 200  4/100 als Satellite. Bootnode war eine ALPHA 2100.

Bei der Umstellung der Botnode auf ALPHA 4100 und VMS 7.1-1H1 booteten alle Workstation vom Typ 200 4/100 sehr langsam.
Es gab Opcom Meldungen der Art:

%%%%%%%%%%% OPCOM 16-JAN-1998 16:14:58.95 %%%%%%%%%%%
(from node GDCW2D at 16-JAN-1998 16:14:57.22)
Message from user SYSTEM on GDCW2D
Event: Frame Check Error from: Node LOCAL:.GDCW2D CSMA-CD Station CSMACD-0, at: 1998-01-16-16:14:57.206+01:00I0.847
eventUid 21621539-8E8D-11D1-8019-AA00040075C4
entityUid 247503AC-8E8C-11D1-8002-AA00040075C4
streamUid 37D28BBD-8E8C-11D1-8002-AA00040075C4

%%%%%%%%%%% OPCOM 16-JAN-1998 16:14:58.95 %%%%%%%%%%%
(from node GDCW2D at 16-JAN-1998 16:14:57.30)
Message from user SYSTEM on GDCW2D
Event: Alignment Error from: Node LOCAL:.GDCW2D CSMA-CD Station CSMACD-0, at: 1998-01-16-16:14:57.304+01:00I0.847
eventUid 2170FBAD-8E8D-11D1-8019-AA00040075C4
entityUid 247503AC-8E8C-11D1-8002-AA00040075C4
streamUid 37D28BBD-8E8C-11D1-8002-AA00040075C4

Lösung:

Die Variable EWA0_MODE war auf FULL DUPLEX TWISTED gestellt. Eine Änderung von EWA0_MODE breachte den gewünschten Erfolg.

Real time web analytics, Heat map tracking